WF,nelec,irrep,spin
or, alternatively
WF,[NELEC=nelec],[SYM[METRY]=irrep],[spin=spin],[CHARGE=charge]
where nelec is the total number of electrons, irrep is the number of
the irreducible representation, and spin equals , where
is
the total spin quantum number. Instead of nelec also charge can be given,
which specifies the total charge of the molecule. For instance, for a calculation in
symmetry with 10 electrons, WF,10,3,0 denotes a
state, and WF,10,1,2 a
state. The charge can also be defined
by setting the variable CHARGE:
This charge will be used in all energy calculations following this input. Not that SET is required, since CHARGE is a system variable (cf. section 6.3).
Although in principle each program unit requires a WF command, in practice
it is seldom necessary to give it. The program remembers the information on the
WF card, and so one might typically specify the information in an SCF
calculation, but then not in subsequent MCSCF or CI calculations; this also
applies across restarts. Furthermore, nelec defaults to the sum of the
nuclear charges, irrep to 1 and spin to 0 or 1; thus in many cases,
it is not necessary to specify a WF card at all.
molpro@molpro.net